Communication | Protocol | Port | Client | Server | Requirement | ||
---|---|---|---|---|---|---|---|
Legacy Console | TCP | 90 | Administrator browser | Swarm storage node | Pulls information from a Swarm node into the legacy Swarm Admin Console. | ||
Swarm UI | TCP | 91 | Swarm Gateway | Swarm storage node, Gateway | Pulls information from a Swarm node into the Swarm Management UI. Gateway serves this to Administrator clients as service port termination. | ||
SCSP | TCP | 80 | Client application (HTTP client) | Swarm storage node, Gateway | Required
| ||
SCSP | TCP | 6000-6300 | Swarm storage node | Swarm storage node | Required for SCSP communication between cluster nodes. | ||
Prometheus Node Exporter | HTTP | 9100 | Swarm Telemetry VM / Prometheus server | Swarm storage node, Gateway | Optional for Swarm telemetry. | ||
Health Report | HTTPS | 443 | Swarm storage node | DataCore Health Report server (https://swarm.phonehome.datacore.com:443/castor/report | Required to publish Health Report information (seeĀ Health Data to Support). | ||
DHCP | UDP | 67 | Swarm storage node | Swarm Cluster Services (SCS) | Recommended (Required when performing Platform network boot of Swarm storage nodes). | ||
DNS | UDP | 53 | Swarm storage node | Swarm Cluster Services (SCS) | Optional | ||
mDNS | UDP | 5353 | Swarm storage node | Swarm Cluster Services (SCS) | Optional | ||
Multicast | UDP | 7000 | Swarm storage node | Swarm storage node | Optional, but can be configured via Swarm Cluster Services (SCS). | ||
Internode Messaging | UDP | 9003-9300 | Swarm storage node | Swarm storage node | Required for Internode communication between cluster nodes. | ||
NTP | UDP | 123 | Swarm storage node | Swarm Cluster Services (SCS) | Required | ||
Logging | UDP | 514 | Swarm storage node | Swarm Cluster Services (SCS) | Required for Support | ||
SNMP | UDP | 161 | SNMP client | Swarm storage node | Required for Support | ||
TFTP | UDP | 69 | Swarm storage node | Swarm Cluster Services (SCS) | Required | ||
Elasticsearch | TCP | 9200 | Swarm storage node, Gateway | Elasticsearch node | Required when using Gateway S3 and Content Portal. | ||
Elasticsearch Control Plane | TCP | 9300 | Elasticsearch node | Elasticsearch node | Required | ||
Swarm License Server | TCP | 8095 | Swarm storage node | Swarm Cluster Services (SCS) | Required | ||
SCI | TCP | 8080 | Browser on Admin Laptop/Desktop | Swarm Cluster Services (SCS) | Required | ||
vCenter | TCP | 443 | Browser on Admin Laptop/Desktop | Swarm Cluster Services (SCS) | Required for both the Windows system the Pre-Installer is run on, and the SCS server that has direct internet connectivity. |
...