Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Added a known issue

...

  • The 15 series releases can exhibit a known issue when attempting to hot plug drives into a Swarm node that uses the Broadcom/LSI HBA driver based on the kernel version in the release. Customers may experience situations where the hot plug of a known good drive fails, requiring a node restart to allow the drive to be recognized. (SWAR-9873)

  • Multipart uploads result in uploaded objects occupying nearly double the expected size in the cluster. Set ec.segmentConsolidationFrequency to 0 for future Multipart uploads as a workaround. (SWAR-10463)

These are standing operational limitations:

...